Who / when: the lab scientist at the bench, for any test that isn’t sent up automatically by a connected analyzer — a manual method, a read-and-record bench, or a unidirectional instrument that reports to paper and not to Veona. Not every test comes from a machine that talks to Veona, so the result grid doubles as a manual-entry surface. You type the values yourself, but the safety checks — range flagging, the signature, the audit trail — are exactly the same as for an automatic result. The grid is built per test, so a urinalysis shows urinalysis fields and a malaria film shows film fields; you always enter values into the structure that test expects.

We’ll follow Tunde, a lab scientist entering a manually-read result.

  1. Lab Scientist — make sure the sample has been accessioned and barcoded first, on Labs → Accession (covered in Send a Lab Order Down to the Analyzer). Accessioning is what creates the sample the result attaches to.
  2. Lab Scientist — open Labs → Results & Worklist and click the sample in the worklist to open its analytes. The grid shows each analyte this test expects, with its reference range alongside.
  3. Lab Scientist — type each value into the grid. As you type, anything outside the reference range flags automatically — Low, High, Critical Low or Critical High — so you see an out-of-range value the instant you enter it.
  4. Lab Scientist — if you’re not finished (waiting on a repeat, say), press “Save Draft” to keep the values without releasing them. A draft is never visible on the chart or the portal.
  5. Lab Scientist — when the values are complete and checked, press “Verify & Sign Out”. In the “Verify & Release Results” dialog, enter your 6-digit eSign PIN (your electronic signature, separate from your password) and press “Confirm Release”. The result moves to Released.

On release, the ordering physician is notified and the result appears on the chart, and a branded result PDF is generated — identical to an analyzer result, because once it’s signed Veona doesn’t care whether a human or a machine produced the number. A released result can’t be edited; use “Amend (Re-Sign)” and your eSign PIN to issue a corrected version while keeping the original. The release also makes the result eligible for the patient portal — see Release Lab and Imaging Results to the Patient Portal.